Resultados 1 - 20 de 4.551
Filtrar
1.
BMC Infect Dis ; 24(Suppl 1): 313, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486194

RESUMO

INTRODUCTION: International guidelines recommend routine screening for syphilis (aetiological agent: Treponema pallidum subspecies pallidum) amongst key populations and vulnerable populations using tests detecting treponemal and non-treponemal antibodies. Whilst treponemal tests have high sensitivities and specificities, they differ regarding subjective or objective interpretation, throughput and workload. Chemiluminescence immunoassays (CLIAs) are cost- and time-effective automated methods for detecting treponemal antibodies. The Treponema pallidum particle agglutination assay (TPPA) has been considered the "gold standard" treponemal assay, however, this includes a highly manual procedure, low throughput and subjective interpretation. The present multi-country study evaluated the ADVIA Centaur® Syphilis CLIA (Siemens Healthcare) assay compared to the reference SERODIA-TP·PA® (Fujirebio Diagnostics) for the serodiagnosis of syphilis amongst men who have sex with men (MSM). METHOD: 1,485 MSM were enrolled in Brighton (UK), Malta, and Verona (Italy) as part of a larger WHO multi-country and multi-site ProSPeRo study. Ethical approval was obtained. Serum was tested with the ADVIA Centaur® Syphilis CLIA assay and SERODIA-TP·PA®, in accordance with the manufacturers' instructions, for a first round of validation. A second round of validation was carried out for discrepant results that were additionally tested with both Western Blot (Westernblot EUROIMMUN®) and an Immunoblot (INNO-LIA, Fujirebio Diagnostics). Sensitivity, specificity, positive and negative predictive value (PPV and NPV), likelihood ratios (positive/negative), and the Diagnostic Odds Ratio (DOR)/pre-post-test probability (Fagan's nomogram) were calculated. RESULTS: Out of 1,485 eligible samples analysed in the first phase, the SERODIA-TP·PA® identified 360 positive and 1,125 negative cases. The ADVIA Centaur® Syphilis CLIA assay (Siemens) identified 366 positives, missclassifying one TPPA-positive sample. In the second phase, the ADVIA Centaur® Syphilis CLIA resulted in 1 false negative and 4 false positive results. Considering the syphilis study prevalence of 24% (95% CI: 22-26.7), The sensitivity of the ADVIA Centaur® Syphilis CLIA assay was 99.7% (95% CI: 98.5-100), and the specificity was 99.4% (95% CI: 98.7-99.7). The ROC area values were 0.996 (95% CI: 0.992-0.999), and both the PPV and NPV values were above 98% (PPV 98.1%, 95% CI: 96.1-99.2; NPV 99.9%, 95% CI: 99.5-100). CONCLUSIONS: The ADVIA Centaur® Syphilis CLIA assay showed similar performance compared to the SERODIA-TP·PA®. Considering the study is based on QUADAS principles and with a homogeneous population, results are also likely to be generalisable to MSM population but potentially not applicable to lower prevalence populations routinely screened for syphilis. The automated CLIA treponemal assay confirmed to be accurate and appropriate for routine initial syphilis screening, i.e. when the reverse testing algorithm is applied.


Assuntos
Minorias Sexuais e de Gênero , Sífilis , Masculino , Humanos , Treponema pallidum , Homossexualidade Masculina , Anticorpos Antibacterianos , Sorodiagnóstico da Sífilis/métodos , Testes Sorológicos/métodos , Sensibilidade e Especificidade , Medições Luminescentes/métodos , Aglutinação
2.
Drug Discov Ther ; 18(1): 10-15, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38355121

RESUMO

A fluorescence immunochromatography (FIC) kit was developed recently using fluorescent silica nanoparticles coated with a recombinant C-terminal fragment of the surface lectin intermediate subunit (C-Igl) of Entamoeba histolytica to establish rapid serodiagnosis of amebiasis. We further evaluated the system using serum samples from 52 Thai patients with amebiasis. Of the patients, 50 (96%) tested positive using FIC. The samples were also tested using enzyme-linked immunosorbent assay (ELISA) with C-Igl as the antigen. Two samples were negative on ELISA but positive on FIC. The correlation coefficient between the fluorescence intensity using FIC and the optical density value using ELISA was 0.5390, indicating a moderate correlation between the two tests. Serum samples from 20 patients with malaria and 22 patients with Clostridioides difficile infection were also tested using FIC. The false-positive rates were 4/20 (20%) and 1/22 (4%) in patients with malaria and C. difficile infection, respectively. Combining the data from the present study with our previous study, the sensitivity and specificity of FIC were determined to be 98.5% and 95.2%, respectively. The results of the 50 samples were studied using a fluorescence scope and a fluorescence intensity reader, and the findings were compared. Disagreements were found in only two samples showing near-borderline fluorescence intensity, indicating that the use of scope was adequate for judging the results. These results demonstrate that FIC is a simple and rapid test for the serodiagnosis of amebiasis.


Assuntos
Amebíase , Clostridioides difficile , Entamebíase , Malária , Nanopartículas , Humanos , Entamebíase/diagnóstico , Dióxido de Silício , Tailândia , Amebíase/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Testes Sorológicos/métodos , Sensibilidade e Especificidade
3.
J Clin Epidemiol ; 168: 111267, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38307216

RESUMO

OBJECTIVES: Assessing the accuracy of serological tests for SARS-CoV-2 was challenging due to the lack of a gold standard. This study aimed to estimate the accuracy of SARS-CoV-2-specific serological tests using Bayesian latent class models (BLCM) and compare methods with and without a gold standard. STUDY DESIGN AND SETTING: In this study, we analyzed 356 samples-254 positives, ie, from individuals with a previous SARS-CoV-2 infection diagnosis, and 102 negatives, ie, prepandemic samples-using six different rapid serological tests and one laboratory assay. A BLCM was employed to concurrently estimate the sensitivity and specificity of all serological tests for the immunoglobulin (Ig) M and IgG antibodies specific for SARS-CoV-2. Noninformative priors were used. A sensitivity analysis was conducted considering three methods: 1) reverse transcription-polymerase chain reaction test (RT-PCR) as the gold standard, 2) BLCM with RT-PCR as an imperfect gold standard, and 3) frequentist latent class model (LCM). All analyses used software R version 4.3.0, and BLCM were fitted using package runjags using the software JAGS (Just Another Gibbs Sampler). RESULTS: The BLCM-derived sensitivity for IgM varied from 10.7% [95% credibility interval (CrI):1.9-24.6] to 96.9% (95% CrI: 91.0-100.0), with specificities ranging from 48.3% (95% CrI: 39.0-57.6) to 98.9% (95% CrI: 96.2-100.0). Sensitivity for IgG varied between 76.9% (95% CrI: 68.2-84.7) and 99.1% (95% CrI: 96.1-100.0), and specificity ranged from 49.9% (95% CrI: 19.4-95.8) to 99.3% (95% CrI: 97.2-100.0). LCM results were comparable to BLCM. Considering the RT-PCR as a gold standard underestimated the tests' sensitivity, particularly for IgM. CONCLUSION: BLCM-derived results deviated from those using a gold standard, which underestimated the tests' characteristics, particularly sensitivity. Although Bayesian and frequentist LCM approaches yielded comparable results, BLCM had the benefit of enabling credibility interval computation even when sample power is limited.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Análise de Classes Latentes , Teorema de Bayes , Testes Sorológicos/métodos , Sensibilidade e Especificidade , Imunoglobulina G , Imunoglobulina M , Teste para COVID-19
4.
Lancet Microbe ; 5(3): e301-e305, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38224703

RESUMO

The COVID-19 pandemic led to the rapid development of tests to diagnose SARS-CoV-2 infection and ascertain the prevalence of infection, along with the formulation of various treatments and vaccines. Globally, over 220 anti-SARS-CoV-2 serological assays have been developed for laboratory use, and many of these assays are currently used to assess immune responses against SARS-CoV-2. However, because these assays were independently developed by different manufacturers with different target antigens, immunoglobulin detection, technologies, and data reporting approaches, the results are not directly comparable, making it challenging to draw conclusions regarding immune responses at the population level. With deficiencies in assay validation, standardisation, and harmonisation, the inability to use and compare large datasets is becoming a major issue as serological data continue to increase. To help in addressing this issue, WHO established the first International Standard for the anti-SARS-CoV-2 immunoglobulin in late 2020. In this Personal View, we define the WHO International Standard for the anti-SARS-CoV-2 immunoglobulin, summarise the uses of primary versus secondary serology standards, recommend the use of such standards for data harmonisation, and list guidance and resources for using serology standards to improve data comparability.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Pandemias , Técnicas de Laboratório Clínico/métodos , Testes Sorológicos/métodos , Anticorpos Antivirais , Sensibilidade e Especificidade , Organização Mundial da Saúde
5.
Sci Rep ; 14(1): 1421, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228735

RESUMO

Diagnosis of SARS-CoV-2 virus is mainly based on direct detection. Determination of specific antibodies has been used mostly for epidemiological reasons. However, select immunoassays showed good correlation to plaque reduction virus neutralization test (PRNT) in smaller patient cohorts, which suggests their potential as predictors of virus neutralization titer. A total of 3,699 samples from Covid-19 patients were included in the multicentric study performed in the Czech Republic. Anti-SARS-CoV-2 antibody levels were evaluated by 8 commercial antibody assays. Simultaneously, PRNT evaluations were performed with the SARS-CoV-2 B.1.258 variant. All immunoassays showed an overall high true positive diagnostic value ranging from 79.17 to 98.04%. Several commercial EIA methods showed highly positive correlation between the assay results and PRNT levels, e.g., Liaison CoV-2 TrimericS IgG DiaSorin (Spearman r = 0.8833; Architect SASRS-CoV-2 IgG Abbott (r = 0.7298); NovaLisa SARS-CoV-2 IgG NovaTec (r = 0.7103) and Anti-SARS-CoV-2 ELISA IgG Euroimmun (r = 0.7094). While this correlation was less positive for other assays, those, conversely, presented higher true positive values. For most immunoassays, the positive percent agreement of the results was ≥ 95% in sera exhibiting PRNT levels of 1:80 and higher. The assays tested have shown variable correlation to PRNT. Those possessing high positive predictive values serve well as qualitative tests, while others can be utilised as quantitative tests highly predictive of neutralization antibody levels.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Testes Sorológicos/métodos , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina G , Testes de Neutralização/métodos , Anticorpos Neutralizantes
6.
Crit Rev Clin Lab Sci ; 61(1): 70-88, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37800891

RESUMO

Laboratory testing has been a key tool in managing the SARS-CoV-2 global pandemic. While rapid antigen and PCR testing has proven useful for diagnosing acute SARS-CoV-2 infections, additional testing methods are required to understand the long-term impact of SARS-CoV-2 infections on immune response. Serological testing, a well-documented laboratory practice, measures the presence of antibodies in a sample to uncover information about host immunity. Although proposed applications of serological testing for clinical use have previously been limited, current research into SARS-CoV-2 has shown growing utility for serological methods in these settings. To name a few, serological testing has been used to identify patients with past infections and long-term active disease and to monitor vaccine efficacy. Test utility and result interpretation, however, are often complicated by factors that include poor test sensitivity early in infection, lack of immune response in some individuals, overlying infection and vaccination responses, lack of standardization of antibody titers/levels between instruments, unknown titers that confer immune protection, and large between-individual biological variation following infection or vaccination. Thus, the three major components of this review will examine (1) factors that affect serological test utility: test performance, testing matrices, seroprevalence concerns and viral variants, (2) patient factors that affect serological response: timing of sampling, age, sex, body mass index, immunosuppression and vaccination, and (3) informative applications of serological testing: identifying past infection, immune surveillance to guide health practices, and examination of protective immunity. SARS-CoV-2 serological testing should be beneficial for clinical care if it is implemented appropriately. However, as with other laboratory developed tests, use of SARS-CoV-2 serology as a testing modality warrants careful consideration of testing limitations and evaluation of its clinical utility.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Estudos Soroepidemiológicos , Teste para COVID-19 , Testes Sorológicos/métodos
7.
J Microbiol Methods ; 217-218: 106874, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38101579

RESUMO

The objective of this study was to validate an indirect enzyme-linked immunoassay (iELISA) using the recombinant proteins, malate dehydrogenase (MDH) and superoxide dismutase (SOD) [CuZn], as antigens and to evaluate its ability to discriminate antibodies produced by vaccination from those induced by infection in the diagnosis of bovine brucellosis. Sera from six groups were evaluated: G1 - culture-positive animals (52 serum samples) (naturally infected); G2 - non-vaccinated animals (28 serum samples) positive in RBT (Rose Bengal test) and 2ME (2-mercaptoethanol test) selected from brucellosis-positive herds; G3 - animals from a brucellosis-free area (32 serum samples); G4 - S19 vaccinated heifers (114 serum samples); G5 - RB51 vaccinated heifers (60 serum samples); G6 - animals inoculated with inactivated Yersinia enterocolitica O:9 (42 serum samples). Diagnostic sensitivity (DSe) and diagnostic specificity (DSp) were estimated using the frequentist approach and the confidence interval (CI) (95%) calculated by the Clopper-Pearson (exact) method. The DSe for iELISA_MDH in the G1 group was 71.7% (CI 95%: 57.6-83.2%) and for the G2 100.0% (CI 95%: 87.7-100.0%), whereas the DSp was 84.4% in the G3 (CI 95%: 67.2-94.7%). For the iELISA_SOD the DSe was estimated 67.3% for the G1 (CI 95%: 52.9-79.7%) and 71.4% for G2 (CI 95%: 51.3-86.8%), while the DSp for G3 was 87.5% (CI 95%: 71.0-96.5%). iELISA_MDH and iELISA_SOD showed potential to be used in the diagnosis of infected animals, increasing the range of serological tests available for the diagnosis of bovine brucellosis, with the advantage of being S-LPS-free. However, none of the tests could differentiate between infection and vaccination.


Assuntos
Brucelose Bovina , Brucelose , Animais , Bovinos , Feminino , Malato Desidrogenase , Ensaio de Imunoadsorção Enzimática/métodos , Brucelose/diagnóstico , Brucelose/veterinária , Testes Sorológicos/métodos , Anticorpos Antibacterianos , Sensibilidade e Especificidade
8.
BMC Infect Dis ; 23(1): 782, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37946107

RESUMO

BACKGROUND: Parasitological investigation of bone marrow, splenic or lymph node aspirations is the gold standard for the diagnosis of visceral leishmaniasis (VL). However, this invasive test requires skilled clinical and laboratory staff and adequate facilities, and sensitivity varies depending on the tissue used. The direct agglutination test (DAT) is a serological test that does not need specialised staff, with just minimal training required. While previous meta-analysis has shown DAT to have high sensitivity and specificity when using parasitology as the reference test for diagnosis, meta-analysis of DAT compared to other diagnostic techniques, such as PCR and ELISA, that are increasingly used in clinical and research settings, has not been done. METHODS: We conducted a systematic review to determine the diagnostic performance of DAT compared to all available tests for the laboratory diagnosis of human VL. We searched electronic databases including Medline, Embase, Global Health, Scopus, WoS Science Citation Index, Wiley Cochrane Central Register of Controlled Trials, Africa-Wide Information, LILACS and WHO Global Index. Three independent reviewers screened reports and extracted data from eligible studies. A meta-analysis estimated the diagnostic sensitivity and specificity of DAT. RESULTS: Of 987 titles screened, 358 were selected for full data extraction and 78 were included in the analysis, reporting on 32,822 participants from 19 countries. Studies included were conducted between 1987-2020. Meta-analysis of studies using serum and DAT compared to any other test showed pooled sensitivity of 95% (95%CrI 90-98%) and pooled specificity of 95% (95%CrI 88-98%). Results were similar for freeze-dried DAT and liquid DAT when analysed separately. Sensitivity was lower for HIV-positive patients (90%, CrI 59-98%) and specificity was lower for symptomatic patients (70%, CrI 43-89%). When comparing different geographical regions, the lowest median sensitivity (89%, CrI 67-97%) was in Western Asia (five studies). CONCLUSIONS: This systematic review and meta-analysis demonstrates high estimated pooled sensitivity and specificity of DAT for diagnosis of VL, although sensitivity and specificity were lower for different patient groups and geographical locations. This review highlights the lack of standardisation of DAT methods and preparations, and the lack of data from some important geographical locations. Future well-reported studies could provide better evidence to inform test implementation for different patient populations and use cases. PROSPERO REGISTRATION: CRD42021240830.


Assuntos
Soropositividade para HIV , Leishmaniose Visceral , Humanos , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/parasitologia , Testes de Aglutinação/métodos , Testes Sorológicos/métodos , Sensibilidade e Especificidade
9.
Trop Biomed ; 40(3): 337-343, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37897167

RESUMO

Antibody cross-reactivity among flaviviruses is a major limitation in understanding the prevalence without vector control measures. In this study, we investigated the presence of Zika virus (ZIKV)-specific antibodies and the significance of their cross-reactivity with other flaviviruses, which could affect the serological specificity in both symptomatic and asymptomatic pregnant women. Among the results obtained from 217 serum samples tested for ZIKV-specific IgM and IgG, no specific predictions regarding seropositivity or exposure due to extensive cross-reactivity with dengue virus (DENV) serology could be made. Clear-cut positivity was observed in 1.8% (n = 4) and 1.0% (n = 2) for ZIKV IgM and IgG, respectively. The same samples assessed for DENV showed 1.3% (n = 3) seropositivity each for IgM and IgG levels. None of the samples were positive for ZIKV and DENV IgM or IgG. However, one sample (0.4%) tested positive for ZIKV and DENV IgM. No significant correlation was observed between DENV IgM and IgG when comparing the overlapped serotiters. On the other hand, the ZIKV IgG-positive sample showed higher serotiters for DENV IgG, indicating cross-reactivity with ZIKV but without statistical significance. Therefore, screening for the incidence of ZIKV becomes particularly challenging in a population where the presence or pre-exposure to DENV is observed. Our observations further suggest that unless flavivirus prevalence is properly addressed, determining the prevalence of ZIKV antibodies, which may be confounded with other uninvestigated flaviviruses, will be complicated.


Assuntos
Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , Humanos , Feminino , Gravidez , Infecção por Zika virus/diagnóstico , Gestantes , Anticorpos Antivirais , Testes Sorológicos/métodos , Imunoglobulina G , Imunoglobulina M , Reações Cruzadas , Dengue/diagnóstico
10.
BMC Biotechnol ; 23(1): 46, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875853

RESUMO

BACKGROUND: Brucellosis remains one of the global health concerns that reemerges in recent years. Delayed or inaccurate diagnosis end to a long treatment duration and financial burden; therefore, finding a good antigen for detection of specific anti-Brucella antibodies is crucial. We intended to evaluate the serodiagnosis value of recombinant Brucella outer membrane protein 19 kDa (rOMP19) using indirect ELISA system compared with Rose Bengal test. RESULTS: The OMP19 sequence was successfully cloned into pET-28a and produced in E. coli cells (DE3). After extraction and purification of rOMP19, this protein was used for designing indirect ELISA to detect anti-Brucella antibodies in 73 human sera, including 6 brucellosis-positive and 67 brucellosis-negative samples. The accuracy of rOMP19 ELISA was evaluated by receiver operating characteristic (ROC) curve and then compared with Rose Bengal plate test and a commercial anti-IgG Brucella ELISA kit. In comparison with Rose Bengal plate test, the area under the ROC curve was 0.985 (95% CI, 0.96-1.00). From coordinates of the curve, the optimal cut-off value was selected at 0.147, in which the diagnostic sensitivity was 100%, and the specificity was 94%. At this cut-off point, 10 samples were diagnosed as positive (6 true positives and 4 false positives), while negative samples were all correctly diagnosed. The results of our designed rOMP19 ELISA was the same as data obtained from commercial ELISA kit, which applied LPS as an antigen. CONCLUSIONS: We concluded that OMP19 is an efficient antigen for the serodiagnosis of human brucellosis.


Assuntos
Brucelose , Escherichia coli , Humanos , Escherichia coli/genética , Rosa Bengala , Brucelose/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Proteínas Recombinantes/genética , Testes Sorológicos/métodos , Anticorpos Antibacterianos , Sensibilidade e Especificidade
11.
Rev Med Suisse ; 19(845): 1830-1834, 2023 Oct 11.
Artigo em Francês | MEDLINE | ID: mdl-37819179

RESUMO

Although rare, false-positive results from infectious serology tests can mislead the practitioner and have harmful consequences for the patient. The causes are not always clear, but there are certain principles that are important to be aware of, and that help to interpret these diagnostic puzzles correctly. Similarities between different families of pathogens, the technical characteristics of the tests used, the use of therapeutic human immunoglobulins, the detection of vaccine-induced antibodies or even the detection of vaccine antigens themselves can cause non-specific reactions. This article uses examples from routine laboratory practice to illustrate the problem and draw the attention of the treating physician to this issue.


Bien que rares, les résultats faussement positifs des tests de sérologies infectieuses peuvent induire en erreur le praticien et entraîner des conséquences délétères pour le patient. Leurs causes ne sont pas toujours claires, mais certains principes sont importants à connaître et permettent d'interpréter correctement ces casse-têtes diagnostiques. Des similarités entre différentes familles de pathogènes, les caractéristiques techniques des tests utilisés, l'utilisation d'immunoglobulines humaines thérapeutiques, la détection d'anticorps induits par des vaccins ou même la détection des antigènes vaccinaux eux-mêmes peuvent causer des réactions non spécifiques. Cet article illustre ce problème par des exemples tirés de la routine du laboratoire afin d'attirer l'attention du médecin traitant sur ce problème.


Assuntos
Testes Hematológicos , Vacinas , Humanos , Reações Falso-Positivas , Testes Sorológicos/métodos , Laboratórios
12.
Clin Chem Lab Med ; 61(12): 2084-2093, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37540644

RESUMO

The total testing process harmonization is central to laboratory medicine, leading to the laboratory test's effectiveness. In this opinion paper the five phases of the TTP are analyzed, describing, and summarizing the critical issues that emerged in each phase of the TTP with the SARS-CoV-2 serological tests that have affected their effectiveness. Testing and screening the population was essential for defining seropositivity and, thus, driving public health policies in the management of the COVID-19 pandemic. However, the many differences in terminology, the unit of measurement, reference ranges and parameters for interpreting results make analytical results difficult to compare, leading to the general confusion that affects or completely precludes the comparability of data. Starting from these considerations related to SARS-CoV-2 serological tests, through interdisciplinary work, the authors have highlighted the most critical points and formulated proposals to make total testing process harmonization effective, positively impacting the diagnostic effectiveness of laboratory tests.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Pandemias , Teste para COVID-19 , Testes Sorológicos/métodos , Anticorpos Antivirais
13.
PLoS Negl Trop Dis ; 17(8): e0011535, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37540724

RESUMO

Endemic in Brazil, visceral leishmaniasis (VL) is a zoonotic infection that is among the most important parasitic diseases transmitted by vectors. Dogs are the main reservoirs of canine leishmaniasis (CanL) and their identification is used in some countries as part of disease prevention and control measures in the canine and human population. In this context, serological tests are necessary, composed of antigens capable of correctly identifying infected dogs, minimizing the number of false-negative cases. This study aimed to identify more immunoreactive peptides derived from two previously described whole proteins (rDyn-1 and rKDDR-plus) and compare their performance to the control antigens rK39 and the crude extract for the detection of dogs infected with L. infantum, especially the asymptomatic ones. The three selected peptides and a mixture of them, along with the rDyn-1, rKDDR-plus, rK39, and crude extract antigens were evaluated using indirect ELISA with sera samples from 186 dogs with CanL, being asymptomatic (n = 50), symptomatic (n = 50), co-infected (n = 19), infected with Babesia sp. (n = 7), Ehrlichia sp. (n = 6), T. cruzi (n = 20) and uninfected (n = 34). The results showed that the rDyn-1 protein and the peptide mixture had the highest sensitivity (100% and 98.32%, respectively) and specificity (97.01 and 98.51, respectively). A high degree of kappa agreement was found for rDyn-1 protein (0.977), mixed peptides (0.965), rKDDR-plus protein (0.953), K-plus peptide 1 (0.930) and Dyn-1 peptide (0.893). The mixture of peptides showed the highest likelihood (65.87). The ELISA using the mixture of peptides and the rDyn-1 protein showed high performance for CanL serodiagnosis. More mix combinations of the peptides and additional extended field tests with a larger sample size are recommended.


Assuntos
Doença de Chagas , Doenças do Cão , Leishmania infantum , Leishmaniose Visceral , Humanos , Cães , Animais , Antígenos de Protozoários , Sensibilidade e Especificidade , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/veterinária , Leishmaniose Visceral/epidemiologia , Peptídeos , Immunoblotting , Oligopeptídeos , Ensaio de Imunoadsorção Enzimática/métodos , Testes Sorológicos/métodos , Doenças do Cão/epidemiologia , Anticorpos Antiprotozoários
14.
Am J Clin Pathol ; 160(6): 599-602, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549102

RESUMO

OBJECTIVES: Recently modified 2-tier testing (MTTT) algorithms using 2 enzyme immunoassays (EIAs) as opposed to an EIA followed by immunoblot have been approved by the US Food and Drug Administration (FDA) for the screening and confirmation of Lyme disease. The Quidel Sofia Lyme fluorescent immunoassay is a rapid lateral-flow method that can be performed in real time, permitting on-demand testing. We evaluated the performance of the Sofia assay as a first-tier test in an MTTT algorithm. METHODS: We compared the Sofia Lyme test with the Zeus ELISA Borrelia VlsE1/pepC10 lgG/IgM test, followed by the Zeus monovalent IgM/IgG EIA as the confirmatory test. RESULTS: When used as a first-tier test compared with a standard Zeus MTTT assay, the positive percentage agreement was 91.4%% (95% CI, 77.6%-97.0%). The negative percentage agreement was 100% (95% CI, 94.0%-100%). The overall agreement was 98.3% (95% CI, 94.2%-99.4%). κ = 0.945, indicating "almost perfect agreement." CONCLUSIONS: The Sofia Lyme test performs well compared with an FDA-approved MTTT.


Assuntos
Borrelia , Doença de Lyme , Humanos , Sensibilidade e Especificidade , Anticorpos Antibacterianos , Testes Sorológicos/métodos , Imunoglobulina G , Doença de Lyme/diagnóstico , Ensaio de Imunoadsorção Enzimática , Algoritmos , Corantes , Imunoglobulina M
15.
J Vis Exp ; (197)2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37522730

RESUMO

To monitor the progression of infectious diseases, it is useful to assess immunoreactivity against various antigenic determinants, and measure different antibody isotypes because they appear at different stages of the host immune response. With Lyme borreliosis, the pathogenic agent can be one of the multiple members of the Borrelia species. Therefore, correct sample classification requires evaluating the immunoreactivity against different antigens of different Borrelia species. Additionally, anti-pathogen IgG and IgM responses can have different elicitation time courses during disease progression. Here we demonstrate the development of a two-reporter multiplex immunoassay that has utility in identifying Borrelia-specific immune response in human serum samples by simultaneously evaluating both IgG and IgM immunoreactivity against different bacterial antigens in the same reaction well. This dual-reporter approach retains the analytical performance of single-reporter methods while conserving time and resources and reducing sample size requirements. This assay allows essentially double the serological information to be generated from a blood sample in half the time.


Assuntos
Borrelia burgdorferi , Doença de Lyme , Humanos , Imunoglobulina G , Sensibilidade e Especificidade , Anticorpos Antibacterianos , Doença de Lyme/diagnóstico , Antígenos de Bactérias , Imunoglobulina M , Testes Sorológicos/métodos
16.
J Infect Public Health ; 16(9): 1435-1442, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37517370

RESUMO

BACKGROUND: Zika Virus (ZIKV) is a re-emerging, arthropod-borne flavivirus transmitted by Aedes mosquitoes (Ae. aegypti and Ae. albopictus). The coexistence of dengue virus (DENV) and ZIKV concurrently has been associated with a wide array of neurological complications, which may influence the clinical outcomes of infections. Sri Lanka witnessed a severe dengue epidemic in 2017, characterized by extraordinary and severe disease manifestations with considerable morbidity. Therefore, this study assessed the potential occurrence of ZIKV infection during DENV outbreak in Sri Lanka from 2017 to 2019, which could bear substantial implications for public health. METHODS: Five hundred ninety-five serum samples were procured from individuals suspected of dengue and admitted to Kandy National Hospital between 2017 and 2018 and the Negombo District General Hospital between 2018 and 2019. These samples underwent quantitative real-time RT-PCR (qRT-PCR) to identify the presence of the ZIKV gene, while enzyme-linked immunosorbent assay was employed to detect ZIKV-specific IgM and IgG antibodies. Focus reduction neutralization tests were subsequently conducted to confirm ZIKV infection. RESULTS: Among the 595 serum samples, 6 (1.0%) tested positive for ZIKV using qRT-PCR. Anti-ZIKV IgM and IgG were identified in 18.0% and 38.6% patients. Sixty-six (11.0%) samples demonstrated the presence of anti-ZIKV IgM and IgG. Within ZIKV IgM-positive samples, 2.2% exhibited neutralizing antibodies against ZIKV. Through the implementation of qRT-PCR, ZIKV IgM detection, and neutralization testing, 2% and 3.7% cases of ZIKV infections were confirmed in the Kandy and Negombo regions, respectively. CONCLUSION: This study is the inaugural endeavor to substantiate the existence of ZIKV infection in Sri Lanka utilizing molecular and serological analysis. The findings of this investigation imply that ZIKV was circulating throughout the 2017-2019 DENV outbreak. These results underscore the necessity for improved preparedness for future outbreaks, fortifying governmental policies on public health, and establishing effective early warning systems regarding the emergence of these viruses.


Assuntos
Aedes , Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , Animais , Humanos , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/epidemiologia , Sri Lanka/epidemiologia , Dengue/diagnóstico , Testes Sorológicos/métodos , Anticorpos Antivirais , Imunoglobulina G , Imunoglobulina M
17.
Medicine (Baltimore) ; 102(29): e34133, 2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37478238

RESUMO

This study aimed to evaluate the diagnostic value of chemiluminescence immunoassay (CLIA), passive particle agglutination (PPA), and indirect immunofluorescence assay (IFA) in detecting Mycoplasma pneumoniae infection in children. Serum samples from 165 children with acute community-acquired respiratory tract infections were examined using CLIA, PPA, and IFA, and consistency coefficient, specificity, and sensitivity were analyzed. Compared with the PPA (titer ≥ 1:160), the consistency coefficients of the immunoglobulin(Ig)M-CLIA, immunoglobulin(Ig)G-CLIA and IgM-IFA methods were 93.94%, 75.76%, and 83.64%, respectively. The positive likelihood ratio (PLR) and specificity of IgM-CLIA was 19.40 and 95.49%, respectively. The consistency coefficient of (IgM+IgG)-CLIA and PPA (titer ≥ 1:160) was 89.1%, and the sensitivity and negative predictive value of (IgM+IgG)-CLIA were 96.88% and 98.94%, respectively. CLIA MP-IgM has high concordance with PPA, and its specificity and sensitivity are higher than those of CLIA MP-IgG and IFA MP-IgM, suggesting its better diagnosis of early MP infection. The sensitivity and negative predictive value of CLIA MP (IgM+IgG) were higher than those of PPA or IFA, indicating that it should be considered as a priority in the diagnosis of MP infection.


Assuntos
Infecções Comunitárias Adquiridas , Pneumonia por Mycoplasma , Infecções Respiratórias , Humanos , Criança , Mycoplasma pneumoniae , Imunoglobulina M , Imunoglobulina G , Anticorpos Antibacterianos , Pneumonia por Mycoplasma/diagnóstico , Testes Sorológicos/métodos , Infecções Respiratórias/diagnóstico , Infecções Comunitárias Adquiridas/diagnóstico
18.
J Infect Dev Ctries ; 17(5): 693-699, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37279431

RESUMO

INTRODUCTION: Leishmaniasis is a major health problem and its diagnosis still represents a challenge. Since consistent evidence on the comparison of serological methods is lacking, our work aims to compare five serological tests for the diagnosis of visceral and asymptomatic leishmaniasis in southern France, a region where leishmaniasis is endemic. METHODOLOGY: Serum samples from 75 patients living in Nice, France were retrospectively analyzed. They included patients affected by visceral leishmaniasis (VL; n = 25), asymptomatic carriers (AC; n = 25) and negative controls (n = 25). Each sample was tested using two immunochromatographic tests (ICT; IT LEISH® and TruQuick IgG/IgM®), an indirect fluorescent antibody test (IFAT) and two Western Blotting (WB; LDBio BIORAD® and an in-house method). RESULTS: Diagnosis of VL with IFAT and TruQuick® showed the highest diagnostic performance parameters. IFAT had 100% sensitivity and specificity, while TruQuick had 96% sensitivity and 100% specificity. Finally, the two tests showed high accuracy (100% for IFAT and 98% for TruQuick) for the AC group. WB LDBio® was the only method able to detect Leishmania latent infection, with a sensitivity of 92%, and a specificity of 100%, with a Negative Predictive Value (NPV) of 93%. This performance is reflected in the high accuracy of the test. CONCLUSIONS: The data obtained with TruQuick® supports its application in the rapid diagnosis of leishmaniasis in endemic areas, a feature not shown by IFAT despite its high diagnostic performance. Regarding the diagnosis of asymptomatic leishmaniasis, the best results were obtained with WB LDBio®, confirming previous studies.


Assuntos
Doenças do Cão , Leishmania , Leishmaniose Visceral , Humanos , Animais , Cães , Estudos Retrospectivos , Leishmaniose Visceral/epidemiologia , Testes Sorológicos/métodos , Sensibilidade e Especificidade , Anticorpos Antiprotozoários , Ensaio de Imunoadsorção Enzimática/métodos
19.
Euro Surveill ; 28(21)2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37227301

RESUMO

BackgroundSerological surveys have been the gold standard to estimate numbers of SARS-CoV-2 infections, the dynamics of the epidemic, and disease severity. Serological assays have decaying sensitivity with time that can bias their results, but there is a lack of guidelines to account for this phenomenon for SARS-CoV-2.AimOur goal was to assess the sensitivity decay of seroassays for detecting SARS-CoV-2 infections, the dependence of this decay on assay characteristics, and to provide a simple method to correct for this phenomenon.MethodsWe performed a systematic review and meta-analysis of SARS-CoV-2 serology studies. We included studies testing previously diagnosed, unvaccinated individuals, and excluded studies of cohorts highly unrepresentative of the general population (e.g. hospitalised patients).ResultsOf the 488 screened studies, 76 studies reporting on 50 different seroassays were included in the analysis. Sensitivity decay depended strongly on the antigen and the analytic technique used by the assay, with average sensitivities ranging between 26% and 98% at 6 months after infection, depending on assay characteristics. We found that a third of the included assays departed considerably from manufacturer specifications after 6 months.ConclusionsSeroassay sensitivity decay depends on assay characteristics, and for some types of assays, it can make manufacturer specifications highly unreliable. We provide a tool to correct for this phenomenon and to assess the risk of decay for a given assay. Our analysis can guide the design and interpretation of serosurveys for SARS-CoV-2 and other pathogens and quantify systematic biases in the existing serology literature.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Sensibilidade e Especificidade , Teste para COVID-19 , Testes Sorológicos/métodos , Anticorpos Antivirais
20.
Microbiol Spectr ; 11(3): e0071523, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37222611

RESUMO

Vaccine-induced seroreactivity/positivity (VISR/P) poses a significant and common challenge to HIV vaccine implementation, as up to 95% of vaccine recipients may be misclassified as having HIV infection by current HIV screening and confirmatory serological assays. We investigated whether internal HIV proteins could be used to overcome VISR and discovered a set of 4 antigens (gp41 endodomain, p31 integrase, p17 matrix protein, and Nef) that are recognized by antibodies produced in individuals with HIV infection but not in vaccinated individuals. When evaluated in a multiplex double-antigen bridging ELISA, this antigen combination had specificities of 98.1% prevaccination and 97.1% postvaccination, demonstrating the assay is minimally impacted by vaccine-induced antibodies. The sensitivity was 98.5%, further increasing to 99.7% when p24 antigen testing was included. Results were similar across HIV-1 clades. Although more technical advancements will be desired, this research provides the groundwork for the development of new fourth-generation HIV tests unaffected by VISR. IMPORTANCE While the detection of HIV infection is accomplished by several methods, the most common are serological tests that detect host antibodies produced in response to viral infection. However, the use of current serological tests may present a significant challenge to the adoption of an HIV vaccine in the future because the antibodies to HIV antigens detected in currently available tests also tend to be included as antigens in the HIV vaccines in development. The use of these serological tests may thus result in the misclassification of vaccinated HIV-negative individuals, which can have potential for significant harms for individuals and could prevent the widespread adoption and implementation of HIV vaccines. Our study aimed to identify and evaluate target antigens for inclusion in new serological tests that can be used to identify HIV infections without interference from vaccine-induced antibodies but also fit within existing platforms for HIV diagnostics.


Assuntos
Vacinas contra a AIDS , Infecções por HIV , HIV-1 , Humanos , Infecções por HIV/diagnóstico , Anticorpos Antivirais , Testes Sorológicos/métodos